Add sensor readings for Supermicro/ATEN BMC SNMP monitoring

2 votes

Checkmk finds little information via SNMP on a Supermicro BMC. A number of temperature/speed/voltage sensors are available, I suggest they be added:

.1.3.6.1.4.1.21317.1.3.1.2.1 = STRING: "36.000"
.1.3.6.1.4.1.21317.1.3.1.13.1 = STRING: "CPU1 Temp"

.1.3.6.1.4.1.21317.1.3.1.2.16 = STRING: "28.000"
.1.3.6.1.4.1.21317.1.3.1.13.16 = STRING: "P1-DIMMB1 Temp"

.1.3.6.1.4.1.21317.1.3.1.2.32 = STRING: "2900.000"
.1.3.6.1.4.1.21317.1.3.1.13.32 = STRING: "FAN1"

.1.3.6.1.4.1.21317.1.3.1.2.40 = STRING: "11.764"
.1.3.6.1.4.1.21317.1.3.1.13.40 = STRING: "12V"
.1.3.6.1.4.1.21317.1.3.1.2.41 = STRING: "5.070"
.1.3.6.1.4.1.21317.1.3.1.13.41 = STRING: "5VCC"

.1.3.6.1.4.1.21317.1.3.1.2.55 = STRING: "0.000"
.1.3.6.1.4.1.21317.1.3.1.13.55 = STRING: "Chassis Intru"
.1.3.6.1.4.1.21317.1.3.1.2.56 = STRING: "1.000"
.1.3.6.1.4.1.21317.1.3.1.13.56 = STRING: "PS1 Status"
.1.3.6.1.4.1.21317.1.3.1.2.57 = STRING: "1.000"
.1.3.6.1.4.1.21317.1.3.1.13.57 = STRING: "PS2 Status"